Test data for SSL4044G+ (s/n 410**)
The test equipment used was the Prism Sound dScope with analog in/out converters set to a sample rate of 192kHz. All measurements performed in Sweden (August 2019) with a 10Hz-40kHz sweep at +4dBu. Nominal gain @1kHz is fine trimmed on console faders to unity gain within +/- 0,05dB. Phase response is shown in reference to generator by loopback of dScope channel B. THD+N measured unweighted but with HPF@22Hz and LPF@22kHz.
– – – –
All dScope Test Data Results:
https://drive.google.com/drive/folders/1-IPgJG4zzZZ7shWYPtnsoJMLeb-yYOd2?usp=sharing